Gsi-outdoors PNEG-630 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Séchoirs Gsi-outdoors PNEG-630. GSI Outdoors PNEG-630 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 121
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
2004 Revised Edition
PNEG-630
Troubleshooting and
Reference Manual
GSI
Competitor
& EMCS
Portable Dryer
Models
Competitor Series 2000 Dryer
Vue de la page 0
1 2 3 4 5 6 ... 120 121

Résumé du contenu

Page 1 - Portable Dryer

2004 Revised EditionPNEG-630Troubleshooting andReference ManualGSICompetitor & EMCSPortable DryerModelsCompetitor Series 2000 Dryer

Page 2 - Table Of Contents

Portable Dryer Troubleshooting9FAN #12345 6Error Message - + - + - + - + - + - + RESULTFan # Housing High Temperature J5-12 J1-7 J5-12 J1-8 J5-12 J2-7

Page 3

Portable Dryer Troubleshooting99Fixed Grain Hi-Limit & Temperature SensorPLENUMSCRUNLOADMOTOR1XXRIGHT FIXEDGRAIN HIGHLIMITOUTSIDE LIGHTTEMP.SENSOR

Page 4 - Information

Portable Dryer Troubleshooting100Out of Grain SensorJUNCTIONBOXLOWERGAS PIPE TRAINTEMP. SENSORSLIMITGRAIN HIGHLEFT FIXEDAIR SWITCHSOLENOIDFANJUNCTIONB

Page 5

Portable Dryer Troubleshooting101Grain Temperature SensorBLACK 20 GA.WHITE/BLACK STRIP 20 GA.REARFRONTWHITE/BLACK STRIP J7-13PLENUM TEMP SENSORINSIDE

Page 6

Portable Dryer Troubleshooting102Grain Sensor TestingSENSORS COMP98.PRTIF OHMS DOES NOT = 11.0 K CHECK LOWER AND UPPER TERMINAL STRIP (J7-13 GND &

Page 7

Portable Dryer Troubleshooting103Grain SensorProcedure for Locating, Testing and Replacinga Defective Grain Temperature Sensor Symptoms

Page 8 - Equipment

Portable Dryer Troubleshooting104 Procedure for Locating, Testing and Replacinga Defective Grain Temperature Sensor. (continued) 11. Now

Page 9 - Safety Sign-Off Sheet

Portable Dryer Troubleshooting105 Procedure for Locating, Testing and Replacinga Defective Grain Temperature Sensor. (continued) 3.

Page 10 - Safety Voltage Check Points

Portable Dryer Troubleshooting106Plenum Sensor Procedure for Locating, Testing and Replacing a Defective Ple

Page 11

Portable Dryer Troubleshooting107 Procedure for Locating, Testing and Replacing

Page 12 - EMCS Display Board

Portable Dryer Troubleshooting108Stern and Capacitor Diagram 10-17 HP 1PhaseWIRE #8 FROM MOTORWIRE #5 FROM MOTORWIRE #1 FROM MOTOR216-259uF, 250VAC CA

Page 13 - Wiring Reference

Portable Dryer Troubleshooting10Programming Instructions for EMCS Grain DryersProgramming1. Turn Control Power on dryer to off.2. Locate programming

Page 14 - Switch Light Block - D01-0455

Portable Dryer Troubleshooting109OPERATION HINTS FOR COMPETITOR DRYERS Present Software version

Page 15

Portable Dryer Troubleshooting110 6. OPERATION HINTS 1. If you set a new timer setting which is lower then the present setting it becomes effective im

Page 16

Portable Dryer Troubleshooting111Series 100 Error ConditionsThis indicates that one of the other onscreen errors (vapor, plenum, housingtemp hi-limit,

Page 17

Portable Dryer Troubleshooting112Series 100 Error Conditions PLENUMERRORTHIS DISPLAY INDICATES A LOSS OF AIRPRESSURE INSIDE THE DRYER. THIS ISUSUALLY

Page 18

Portable Dryer Troubleshooting113Heater CircuitJ7-19 FLAME DETECTION ORANGE -J6-07-IGNITION NEUTRAL---WHITEJ6-06-IGNITION POWER---BLACKJ7-13-VAPOR-PUR

Page 19

Portable Dryer Troubleshooting114J7-10 12VDC NEGATIVE WHITE/BLACK STRIP1PINKWHITEBROWNGREYJ7-02 HOUSING HIGH LIMITJ6-14 CYCLE SOLENOID POWERJ6-13 MAIN

Page 20

Portable Dryer Troubleshooting115S228LP.PRTJ7-10 WHT/BLKJ7-02 YELJ7-08 REDJ7-13 PURJ6-14 BRNJ6-13 WHTJ6-12 BLKJ6-06 BLKJ6-07 WHTJ7-20 WHTJ7-

Page 21

Portable Dryer Troubleshooting116Series 100 Natural Gas 26"/28" FanS228NG.PRTJ7-10 WHT/BLKJ7-02 YELJ7-08 REDJ6-14 BRNJ6-13 WHTJ6-12 BL

Page 22

Portable Dryer Troubleshooting117Series 100 LP 36"/42" FanYELPURBLKWHTYELPURWHTBRNBLKBLKBLKJ7-10 WHT/BLKJ7-02 YELJ7-08 REDJ7-13 PURJ6-14

Page 23 - Plenum Hi-Temperature Switch

Portable Dryer Troubleshooting118Series 100 Natural Gas 36"/42" FanYELBLKWHTYELWHTBRNBLKBLKBLKJ7-10 BLK/WHTJ7-02 YELJ7-08 REDJ6-14 BRNJ6-

Page 24 - Fixed Grain Hi-Limit

Portable Dryer Troubleshooting11TO STOP SW.TO START SW.TO START & STOP SWS.321DISPLAYRIBBONS1U12P3COMMUNICATIONS CABLE TO I/O BOARDP5P4KEY P

Page 25

Portable Dryer Troubleshooting119WarrantyEXCEPT FOR THE ABOVE STATED EXPRESS LIMITED WARRANTIES, GSI MAKES NO WAR-RANTY OF ANY KIND, EXPRESSED OR IMPL

Page 26

1004 E. Illinois St.Assumption, IL 62510-0020Phone 217-226-44212004 Edition

Page 27

Portable Dryer Troubleshooting12 Wiring ReferenceInput/Output Board Identification1357924681012141618201113151719J11357924681012141618201113151719J213

Page 28 - AND ORANGE WIRES

Portable Dryer Troubleshooting13Switch Replacement for EMCS DryerSwitch N/O Contact Block - Part No. D63-0006Switch Light Block - D01-0455Switch Repla

Page 29

Portable Dryer Troubleshooting14 Wiring Reference1100 Series Control Box WiringNEED JUMPERNEED JUMPERREDJ5-8120 VAC (BLACK)AC 1120 VAC NEUT

Page 30 - Motor Overloads

Portable Dryer Troubleshooting15 Wiring Reference1100 Series Control Box Wiring (New Version)

Page 31 - PRESSURE SWITCH SAFETY

Portable Dryer Troubleshooting16 Wiring Reference1200 Series Control Box Wiring52 TOTAL TERMINALSSAFETY CIRCUITNEED JUMPERNEED JUMPERRED53 TOTAL TERMI

Page 32 - Air Pressure Switch Drawing

Portable Dryer Troubleshooting17 Wiring Reference1200 Series Control Box Wiring (New Version)

Page 33 - Out of Grain Safety Circuit

Portable Dryer Troubleshooting18J8-16 WHITE - AC NEUTRAL - UNLOAD NEUTRAL35 - D01-0531 ENTRELEC TERMINALS2 - D01-0533 END STOPS1 - D01-0532 BLANK P

Page 34

Portable Dryer Troubleshooting1Table Of ContentsSafety ...

Page 35 - TO UPPER CONTROL BOX

Portable Dryer Troubleshooting191200 Fan Lower Control Box Interconnect StripS2 ORANGE - TEMPERATURE SENSORS1 ORANGE - TEMPERATURE SENSORB2WHITE - AC

Page 36 - AFTER MARCH 1, 1997

Portable Dryer Troubleshooting20YELLOW FROM J1-05 TO PLENUM HIGH LIMIT SWITCHWHITE TO S1 FROM GRAIN TEMPERATURE SENSORBLACK TO S2 FROM GRAIN TEMPERATU

Page 37 - METER ROLL SENSOR

Portable Dryer Troubleshooting21Fan Housing and Vapor Hi-Limit Circuit Wiring Reference

Page 38 - IMPORTANT

Portable Dryer Troubleshooting22Plenum Hi-Temperature Switch Wiring Reference

Page 39 - Lower Junction Box Wiring

Portable Dryer Troubleshooting23Fixed Grain Hi-Limit Wiring Reference

Page 40

Portable Dryer Troubleshooting24 Grain & Plenum Hi-Limit LocationsPLENUMSCRUNLOADMOTOR11XXRIGHT FIXEDGRAIN HIGHLIMITOUTSIDE LIGHTTEMP. SENSORSLOAD

Page 41 - Measure Flame Current

Portable Dryer Troubleshooting252FNLMTSW98.PRT REV. DATE 4/5/98RED TO J1-05BLUE TO J1-11YELLOW TO J1-12 FAN #1PLENUM HIGH LIMIT SWITCHD03-0

Page 42 - Flame Control Circuit

Portable Dryer Troubleshooting26Rear Discharge & Emergency Cooling Circuit Wiring Reference

Page 43

Portable Dryer Troubleshooting27Rear Discharge Mercury SwitchPOSITIONED WITH LID CLOSED ANDSJOW 18/2 CORD POINTED TOWARDSTHE FRONT OF THE DRYER CONNEC

Page 44

Portable Dryer Troubleshooting28Adjustable Hi-Limit & Emergency Cooling Circuit Wiring Reference

Page 45 - Fan 28 LP Hi/Low-On/Off

Portable Dryer Troubleshooting2Table Of ContentsCompetitor Series 2000 Dryer (Picture of Dryer)(1995 to Present)...

Page 46

Portable Dryer Troubleshooting29Motor Overloads Wiring Reference

Page 47 - Fan 28 NG Hi/Low-On/Off

Portable Dryer Troubleshooting30Air Pressure SwitchJ5-8J1-8J1-6J1-7J1-58J51 112 VOLTDC NEGATIVE12 VOLT SOURCEDC POSITIVEJ2J3INPUT/OUTPUT BOARDTERMINAL

Page 48

Portable Dryer Troubleshooting31HIGHBACKVIEW OF AIR SWITCH ASSEMBLYTO UPPER CONTROL BOXBLUE J1-13 AIRFLOW (N.O.)BLUE J5-08 12VDC POSITIVE CALIBRATED W

Page 49 - Fan 42 LP Hi/Low-On/Off

Portable Dryer Troubleshooting32Out of Grain Safety Circuit Wiring Reference

Page 50

Portable Dryer Troubleshooting33Out of Grain Safety Circuit LocationJUNCTIONBOXLOWERGAS PIPE TRAINTEMP. SENSORSLIMITGRAIN HIGHLEFT FIXEDAIR SWITCHTHER

Page 51 - Fan 42 NG Hi/Low-On/Off

Portable Dryer Troubleshooting34Upper Junction Box DrawingREDWHITETO OUTSIDE LIGHT FIXTUREBLACKBLACKJ5-04TO 12VDC J5-09J9-03L1TO LOAD MERCURY SWITCHWH

Page 52

Portable Dryer Troubleshooting35Meter Roll SensorJ5-09J5-12J5-19J5-16J5-05J1-19TO REAR DISCHARGE SWITCH TO REARJUNCTION BOXLEFT METERROLL SENSORRIGHT

Page 53 - SCR Drive Circuit

Portable Dryer Troubleshooting36Meter Roll Sensor Wiring1997 Dryers have only 1 meter roll board.Remove one meter roll board and tie the 2 T-3 wires

Page 54 - RTD Temperature Sensor

Portable Dryer Troubleshooting37Meter Roll Reversing14913121485 TODC DRIVE MOTORORANGE PURPLE J7-17 NOTE: WHEN INSTALLING RELAY

Page 55 - E.M.C.S. PORTABLE DRYERS

Portable Dryer Troubleshooting38Lower Junction Box WiringWHITE S1BLACK S2RED J1-11ORANGE J1-19BROWN FROM J1-19 TO DISCHARGE SWITCHORANGE FROM J5-05 TO

Page 56

Portable Dryer Troubleshooting3SafetyWARNING! BE ALERT!Personnel operating or workingaround electric fans should read thismanual. This manual must b

Page 57 - Check the Motor

Portable Dryer Troubleshooting39 The B. GND terminal is used to ground the burner and to complete the flame current signal circuit. This terminal is

Page 58 - Fenwal Troubleshooting

Portable Dryer Troubleshooting40Fenwal Board TroubleshootingOn-Board Diagnostics The LED will flash on for 0.2 seconds then off for

Page 59 - Ignitor Tips

Portable Dryer Troubleshooting41CoilV120 SEC SAFETY12 VOLTS DC120 VOLTS ACWHTWHTFENWAL BOARDWHTWHTORCOMMONCOMMONNeutralCOILNormal ClosedNormal ClosedW

Page 60 - Metering Roll Sensors

Portable Dryer Troubleshooting42IGNITORSENSORFLAMEDELAYTIMEE2 S1L2V2L1V1FENWAL PART# HF-462412 VOLTS DC20 SEC SAFETYVAPOR LIMITHOUSING LIMITVAPORHOUS

Page 61 - Airflow Operation

Portable Dryer Troubleshooting43Conversion Diagram For C Series Dryers To A SwitchableHi/Low Burner Or A On/Off Burner Wiring Reference

Page 62 - Temperature

Portable Dryer Troubleshooting44Fan 28 LP Hi/Low-On/Off Wiring Reference

Page 63 - Vapor High Limit Hints

Portable Dryer Troubleshooting45Fan 28 LP Hi/Low-On/Off Burner With Mercoid Wiring Reference

Page 64 - Out Of Grain Warning Shutdown

Portable Dryer Troubleshooting46Fan 28 NG Hi/Low-On/Off Wiring Reference

Page 65 - Motor Overload Shutdown

Portable Dryer Troubleshooting47Fan 28 NG Hi/Low-On/Off Burner With Mercoid Wiring Reference

Page 66

Portable Dryer Troubleshooting48Fan 42 LP Hi/Low-On/Off Wiring Reference

Page 67

Portable Dryer Troubleshooting4SafetySafety decals should be read andunderstood by all people in andaround the dryer area. If the follow-ing safety d

Page 68

Portable Dryer Troubleshooting49Fan 42 LP Hi/Low-On/Off Burner With Mercoid Wiring Reference

Page 69

Portable Dryer Troubleshooting50Fan 42 NG Hi/Low-On/Off Wiring Reference

Page 70

Portable Dryer Troubleshooting51Fan 42 NG Hi/Low-On/Off Burner With Mercoid Wiring Reference

Page 71 - Competitor Wiring Reference

Portable Dryer Troubleshooting52SCR Drive CircuitTo CoilWITH POWER WIRESUPPER POWER STRIP TO TERMINAL ONCONTACTORSCRS C R BoardTo SCR Drive MotorF +F

Page 72

Portable Dryer Troubleshooting53RTD Temperature SensorBLACK 20 GA.WHITE 20 GA.REARFRONTINSIDE GRAIN COLUMN CONDUITTO UPPER CONTROL BOXWHITE S1BLACK S2

Page 73

Portable Dryer Troubleshooting54Test Procedure for E.M.C.S. DryersIF NONE OF THE MEASUREMENTS = 3.4 K,THEN CHECK EACH INDIVIDUAL SENSOR.IF MEASUREMENT

Page 74

Portable Dryer Troubleshooting55Temperature ChartsWe use two (2) different types of sensors (NTC thermistor on the Competitor Series 2000, and anenca

Page 75

Portable Dryer Troubleshooting56• If 220 volts AC is present across input ofthe SCR drive board (L1 and L2) thencheck for voltage across the output of

Page 76 - 220 Volt 1PH

Portable Dryer Troubleshooting57Fenwal Ignition SystemSymptoms: Burner will not light, dryershutdown for "Loss of Flame"Fenwal Ignition Oper

Page 77 - 380, 460 & 575 3PH

Portable Dryer Troubleshooting58• Hearing the solenoids snap on after the10 second purge delay means that poweris coming to and through the Fenwalboar

Page 78 - Series 100 Control Box Wiring

Portable Dryer Troubleshooting5Safety

Page 79 - With Moisture Control Hook Up

Portable Dryer Troubleshooting59HintsMetering Roll SensorsMetering Roll Sensor Operation• The T3 (out) terminal is what deliversthe metering roll info

Page 80

Portable Dryer Troubleshooting60Air Pressure SystemSymptoms: Dryer will indicate a "Loss of Airflow"negatives for the black probe(-) of your

Page 81 - (Upper Control Box)

Portable Dryer Troubleshooting61Symptoms: Dryer runs for only a short period oftime, then a shutdown occurs.erature Operation• This message indicates

Page 82

Portable Dryer Troubleshooting62soon as the burner is turned on. Thevaporizer must be adjusted to solve thisproblem.Using J5-11 as the negative test

Page 83 - CPU/Display Board

Portable Dryer Troubleshooting63Out Of Grain Warning• This message indicated that the dryer hasrun low on grain. The shutdown occurswhen the loading

Page 84 - I/O Board

Portable Dryer Troubleshooting64Troubleshooting TipsThis indicates that one of the Motor Overloadshas tripped, shutting down the dryer. Each of the M

Page 85 - SCR Drive Board

Portable Dryer Troubleshooting65 Competitor Series 2000 Portable

Page 86 - RESISTOR

Portable Dryer Troubleshooting66220 Volt Single (1) Phase Power Drawing Competitor Wiring ReferenceOVERLOAD110 VAC OUTPUT220 VAC INPUTJ6-02AC-1220V FU

Page 87

Portable Dryer Troubleshooting67220 Volt Single (1) Phase Power Drawing (New Version) Competitor Wiring Reference

Page 88

Portable Dryer Troubleshooting68110X0AC13FO1FO120V FUSES110 VAC OUTPUT220 VAC INPUTAC NEUTRALAC-1220V FUSESCONTACTORSCRTRANSFORMERMOTORTO FAN #1MOTORT

Page 89

Portable Dryer Troubleshooting6Safety

Page 90 - 120 VOLT AC OUTPUT

Portable Dryer Troubleshooting69220 Volt Three (3) Phase Power Drawing (New Version) Competitor Wiring Reference

Page 91 - Cpu Board Wiring

Portable Dryer Troubleshooting70 COMPETITOR POWER CIRCUIT

Page 92

Portable Dryer Troubleshooting71 COMPETITOR POWER CIRCUIT

Page 93 - 87654321

Portable Dryer Troubleshooting72 COMPETITOR POWER CIRCUIT

Page 94

Portable Dryer Troubleshooting73Upper Control Box Internal WiringAC1L1L2J6-023FO1FO110XOAC13FI1FI3549YELYELORGORGCOMN/ON/CN/CCOMN/OYELLOAD N/OUSER INS

Page 95 - Programming Competitor

Portable Dryer Troubleshooting74Series 2000 Control Box Wiring (New Version) Competitor Wiring Reference

Page 96

Portable Dryer Troubleshooting75Upper Control Box Wiring220 Volt 1PH Competitor Wiring Reference

Page 97

Portable Dryer Troubleshooting76Upper Control Box Wiring380, 460 & 575 3PHCompetitor Wiring Reference

Page 98 - Air Switch Assembly

Portable Dryer Troubleshooting77 Competitor Wiring ReferenceSeries 100 Control Box Wiring100STRIP98.PRT REV. DATE 3/12/981 - END PROTECTOR# D01-05

Page 99 - Air Switch location

Portable Dryer Troubleshooting78Upper Terminal StripWith Moisture Control Hook UpCompetitor Wiring Reference

Page 100 - Competitor Wiring Reference

Portable Dryer Troubleshooting71. Read and understand the operating manual before trying to operate thedryer.2. Power supply should be OFF for service

Page 101 - FRONT VIEW OF OPEN BOX

Portable Dryer Troubleshooting79Upper Terminal StripWith Moisture Control Relay Hook UpCompetitor Wiring Reference

Page 102 - Grain Temperature Sensor

Portable Dryer Troubleshooting80Moisture Manager to Dryer Wiring(Upper Control Box)Competitor Wiring Reference

Page 103 - Temperature chart

Portable Dryer Troubleshooting81Input/Output Board & Terminal StripPURPURREDRED --- J1-17PUR --- SCR2BLK --- LITEPUR --- J4-01PUR --- J4-02PNKREDR

Page 104 - (Small white

Portable Dryer Troubleshooting82Competitor Control CircuitCPU/Display BoardCompetitor Wiring Reference

Page 105 - Grain Sensor

Portable Dryer Troubleshooting83Competitor Control CircuitI/O BoardCompetitor Wiring Reference

Page 106 - Sensor Chart

Portable Dryer Troubleshooting84Competitor Control CircuitSCR Drive BoardCompetitor Wiring Reference

Page 107 - Plenum Sensor

Portable Dryer Troubleshooting85P3 P2 P1 L1 L2 A-A+MINMAX* The SCR board is located in theupper control box.* Terminals L1 and L2 are the inputtermina

Page 108

Portable Dryer Troubleshooting86A-A+MAXBefore starting the procedure set the dryer up as follows:1. All fan and heater switches to off position and l

Page 109 - 180 OHM 11 WATT

Portable Dryer Troubleshooting87A-A+MINSetting SCR Board Minimum Voltage1. Switch the Moisture Control Switch back to the on position. This will put

Page 110 - Operation Hints

Portable Dryer Troubleshooting88Upper Control Box External WiringTO FAN CONTROL BOXTO AIRSWITCH ASSEMBLYTO LOWER JUNCTION BOXTO UPPER JUNCTION BOXTO P

Page 111

Portable Dryer Troubleshooting8 Date Employer’s Signature Employee_______________________________________________________

Page 112 - Series 100 Error Conditions

Portable Dryer Troubleshooting89Input/Output Board 12 VoltTHESE JUMPERS MUST BE INSTALLEDJ1-1 TO J1-17 - USER SAFETYJ1-1 TO J1-16 - MERCOID SAFETYAC N

Page 113

Portable Dryer Troubleshooting9012 VDC GROUND----MOTOR OVERLOADPLENUM TEMP SENSOROUT OF GRAIN SWITCHSTOP SWITCHSTART SWITCH12VDC NEGATIVEFLAME PROBE B

Page 114 - SECONDARY MIDPOINT GROUNDED

Portable Dryer Troubleshooting91Programing Instructions for Competitor Series Grain Dryers Competitor Wiring Reference1. Turn Control Power on dryer

Page 115

Portable Dryer Troubleshooting92Programmer Hook Up Diagram DB9 JACKPLUG THIS INTO THE PROGRAMMERJ2 CONNECTORSERIES 2000 CABLEPROGRAMMING JACK TO UP

Page 116 - SECONDARY ENDPOINT GROUNDED

Portable Dryer Troubleshooting93Competitor Wiring Reference Programming Instructions Using Palm PilotOn th

Page 117

Portable Dryer Troubleshooting94Programming Competitor Dryer Using Palm PilotPalm PilotD03-0689 (M100)D03- 0688 (IIIC)Hot Sync Cable D03-0694DB-9

Page 118 - PART# HH-1093

Portable Dryer Troubleshooting95Back of Switch Panel LayoutMONITORINGDISPLAYTRANSFORMERFUSEJ619 2012J8J61133J514121920J7STARTSTOP METERING ROLL SPEEDC

Page 119

Portable Dryer Troubleshooting96MONITORINGDISPLAYTRANSFORMERFUSEJ619 2012J8J11133J514121920J7STARTSTOPUNLOADMETERING ROLL SPEEDHEATERCONTROL POWEROUTS

Page 120 - Warranty

Portable Dryer Troubleshooting97GREY J7-11 NO AIRFLOW (N.C.)PLENUMSCRUNLOADMOTOR1XXRIGHT FIXEDGRAIN HIGHLIMITOUTSIDE LIGHTTEMP. SENSORSLOADMOTORLOAD M

Page 121 - 2004 Edition

Portable Dryer Troubleshooting98IMPORTANT: To adjust the air switch the grain columnsneed to be full of grain so that the plenum can build up airpres

Commentaires sur ces manuels

Pas de commentaire